Ventricular assist device

VAD; RVAD; LVAD; BVAD; Right ventricular assist device; Left ventricular assist device; Biventricular assist device; Heart pump; Left ventricular assist system; LVAS; Implantable ventricular assist device; Heart failure - VAD; Cardiomyopathy - VAD

 

Ventricular assist devices (VADs) help your heart pump blood from one of the main pumping chambers to the rest of your body or to the other side of the heart. These pumps are implanted in your body. In most cases they are connected to machinery outside your body.

Description

 

A ventricular assist device has 3 parts:

  • A pump. The pump weighs 1 to 2 pounds (.5 to 1 kilogram). It is placed inside or outside of your belly.
  • An electronic controller. The controller is like a small computer that controls how the pump works.
  • Batteries. The batteries are carried outside your body. They are connected to the pump with a cable that goes into your belly.

You will need general anesthesia when your VAD is implanted. This will make you sleep and be pain-free during the procedure.

During surgery:

  • The heart surgeon opens the middle of your chest with a surgical cut and then separates your breastbone. This allows access to your heart.
  • Next, the surgeon will make space for the pump under your skin and tissue in the upper part of your belly wall.
  • The surgeon will then place the pump in this space.

A tube will connect the pump to your heart. Another tube will connect the pump to your aorta or one of your other major arteries. Another tube will be passed through your skin to connect the pump to the controller and batteries.

The VAD will take blood from your ventricle (main pumping chamber of the heart) through the tube that leads to the pump. Then the device will pump the blood back out to one of your arteries and through your body.

Surgery most often lasts 4 to 6 hours.

There are other types of VADs which can be placed with less invasive techniques to help the left or right ventricle. However, these typically cannot provide as much flow (support) as the surgically implanted ones.

 

Why the Procedure Is Performed

 

You may need a VAD if you have severe heart failure that cannot be controlled with medicine, pacing devices, or other treatments. You may get this device while you are on a waiting list for a heart transplant. Some people who get a VAD are very ill and may already be on a heart-lung support machine.

Not everyone with severe heart failure is a good candidate for this procedure.

 

Risks

 

Risks for this surgery are:

  • Blood clots in the legs that may travel to the lungs
  • Blood clots that form in the device and can travel to other parts of the body
  • Breathing problems
  • Heart attack or stroke
  • Allergic reactions to the anesthesia medicines used during surgery
  • Infections

 

Before the Procedure

 

Most people will already be in the hospital for treatment of their heart failure.

 

After the Procedure

 

Most people who are put on a VAD spend from a few to several days in the intensive care unit (ICU) after surgery. You may stay in the hospital from 2 to 8 weeks after you have had the pump placed. During this time you will learn how to care for the pump.

Less invasive VADs are not designed for ambulatory patients and those patients need to stay in the ICU for the duration of their use. They are sometimes used as a bridge to a surgical VAD or heart recovery.

 

Outlook (Prognosis)

 

A VAD may help people who have heart failure live longer. It may also help improve patients' quality of life.

 

 

References

Aaronson KD, Pagani FD. Mechanical Circulatory Support. In: Bonow RO, Mann DL, Zipes DP, Libby P, Braunwald E, eds. Braunwald's Heart Disease: A Textbook of Cardiovascular Medicine . 10th ed. Philadelphia, PA: Elsevier Saunders; 2015:chap 29.

Mcmurray JJV, Pfeffer MA. Heart failure: management and prognosis. In: Goldman L, Schafer AI, eds. Goldman's Cecil Medicine . 25th ed. Philadelphia, PA: Elsevier Saunders; 2016:chap 59.

Peura JL, Colvin-Adams M, Francis GS, et al. Recommendations for the use of mechanical circulatory support: device strategies and patient selection: a scientific statement from the American Heart Association. Circulation . 2012;126(22):2648-2667. PMID: 23109468 www.ncbi.nlm.nih.gov/pubmed/23109468 .

 
  • Congestive heart failure overview

    Animation

  •  

    Congestive heart failure overview - Animation

    Learn about the types of, causes, health risks and treatment of congestive heart failure.

  • Heart, section through the middle - illustration

    The interior of the heart is composed of valves, chambers, and associated vessels.

    Heart, section through the middle

    illustration

  • Congestive heart failure overview

    Animation

  •  

    Congestive heart failure overview - Animation

    Learn about the types of, causes, health risks and treatment of congestive heart failure.

  • Heart, section through the middle - illustration

    The interior of the heart is composed of valves, chambers, and associated vessels.

    Heart, section through the middle

    illustration

A Closer Look

 

    Self Care

     

      Tests for Ventricular assist device

       

         

        Review Date: 5/5/2016

        Reviewed By: Michael A. Chen, MD, PhD, Associate Professor of Medicine, Division of Cardiology, Harborview Medical Center, University of Washington Medical School, Seattle, WA. Also reviewed by David Zieve, MD, MHA, Isla Ogilvie, PhD, and the A.D.A.M. Editorial team.

        The information provided herein should not be used during any medical emergency or for the diagnosis or treatment of any medical condition. A licensed medical professional should be consulted for diagnosis and treatment of any and all medical conditions. Links to other sites are provided for information only -- they do not constitute endorsements of those other sites. © 1997- A.D.A.M., Inc. Any duplication or distribution of the information contained herein is strictly prohibited.

         
         
         

         

         

        A.D.A.M. content is best viewed in IE9 or above, Firefox and Google Chrome browser.



        Content is best viewed in IE9 or above, Firefox and Google Chrome browser.